Click for more products.
No produts were found.

Thermostat - HE-HT01

Reference:
HE-HT01-WWG
NOK 1,832.00
Color front
Color frame
Product available with different options 0 items
Notify me when available
Add to compare0
Love2
Add to wishlist
Brand:
Similar products
Description

Z-Wave Plus V2 Controlled Thermostat - HE-HT01 from Heltun.

The HELTUN HE-HT01 Advanced Programmable Thermostat for Heating systems can be flush mounted over standard electrical junction boxes. It is designed to maintain a constant room temperature by providing sensors for both ambient and radiant floor heating systems. It is recommended for control of electric heating systems (radiator, convection, electric fireplace), boilers, or electric underfloor heating. Heating elements are directly controlled by a single-pole switch. The maximum load for the HE-HT01 thermostat is 16 Amps (4000W @ 250VAC) which must be connected through a circuit breaker.
The HE-HT01 has an LCD screen, six sensitive capacitive touch control buttons, and two temperature sensors (for ambient air temperature and an external NTC floor sensor). It is also equipped with built-in sensors for humidity, illumination, and energy consumption.
The HE-HT01 integrates a Z-Wave 700 platform module allowing it to be used with Z-Wave home automation systems. The HE-HT01 supports Z-Wave ‘S0’ and ‘S2’ security protocols, SmartStart technology, and can be connected (“associated”) to ten other Z-Wave devices, such as relays, switchers, etc. You can select one of six operation modes either manually, or by using a Z-Wave controller/gateway. As a safety measure, the HE-HT01 protects radiant floor systems from overheating by automatically switching off if the temperature reaches 40°C.
The display has a user-friendly interface, showing: ambient air temperature, floor temperature, user set point, humidity level, current operating mode, time, day of the week, and status of the Z-Wave network and relay. Display brightness adjusts to ambient light conditions automatically making it always easy to read.

  • Communicates via Z-Wave Plus V2 RF (868,42 MHz)
  • RF Range Typical: up to 100m in a free field, up to 30m in buildings
  • Standard and enhanced security: Non-Secure, S0 and S2 Unauthorized, S2 Authorized with Key
  • Over The Air (OTA) firmware upgrades
  • Group for Association: 2 (Group 1 support 1 node; Group 2 support 5 nodes)
  • Relay switching with HELTUN Advanced Zero-Crossing Technology
  • Display: LCD-display 73 x 42mm, black with white icons
  • Display brightness adjustable feature
  • 6 Heating Modes
  • Hysteresis adjustable range: 0,2°C to 10°C (default: 0,5°C)
  • Measured temperature range: -30°C to +80°C
  • Temperature measurement accuracy: ±0.5°C
  • Can be used with different external NTC temperature sensors (1 - 100 kOhm)
  • Floor temperature sensor NTC (10 kOhm, 3 meters length) included
  • Temperature set intervals: 1.0°C to 37.0°C
  • Measured humidity range: 0 - 80% RH
  • Humidity measurement accuracy: ±3.0% RH
  • Internal ambient light sensor measuring range: 0 - 30000 Lux
  • External input trigger feature
  • Child lock feature
  • Energy consumption meter
  • Maximum resistive load: 16А, 4000W @ 250VAC
  • Power Supply: 85-265VAC 50/60Hz, 24-48VDC
  • Power Consumption: 1W

IMPORTANT! Must only be installed by an authorized electrical installer. Private individuals who want to carry out work on the electrical system themselves must first study information from dsb (Directorate for Civil Protection and Emergency Planning) - Electrical work: You can do this yourself

Attention! The floor sensor should be laid in an plastic installation pipe that is cast into the floor. This pipe should be laid as high as possible in the cast (floor underside). The sensor cable can be extended with a high-current cable. The sensor cable should not be laid in parallel with cables carrying large currents, as this may induce unwanted signals.

Note: Wooden floor with electric underfloor heating requires that a floor sensor is connected. Thus, floor temperature is limited to 27°C.

Click here to visit Heltun Support page for Z-Wave 700 Heating Thermostat - HE-HT01

Read moreShow less
Product Details
HE-HT01-WWG

Data sheet

Protocol
Z-Wave Plus V2
Device Type
Thermostat - HVAC
Supports Z-Wave Beaming?
Yes
Supports Z-Wave Network Security?
Yes
Supports Z-Wave Security S0?
Yes
Supports Z-Wave Security S2?
Yes
Firmware Upgradable?
Yes
Power Metering Feature?
Yes
Executive Element
Relay
Switching Capacity
4000W or 16A (resistive) at 250V AC
Nominal Voltage
85-265VAC 50/60Hz, 24-48VDC
Operating Temperature
0°C ~ 50°C
Protection
IP21
Dimensions L x W x H (mm)
89 x 89 x 9 (Front); 53 x 53 x 28 (Back part)
Attachments
User Manual - HE-HT01
User and Installation Manual - Heltun HE-HT01
Download (1.24MB)
Accessories
Reviews
No reviews yet.
Customers who bought this product also bought: